說明書 LG WD-12EFA
Lastmanuals提供軟硬體的使用指南,手冊,快速上手指南,技術資訊的分享,儲存,與搜尋 別忘了:總是先閱讀過這份使用指南後,再去買它!!!
如果這份文件符合您所要尋找的使用指南, 說明書或使用手冊,特色說明,與圖解,請下載它. Lastmanuals讓您快速和容易的使用這份LG WD-12EFA產品使用手冊 我們希望LG WD-12EFA的使用手冊能對您有幫助
Lastmanuals幫助您下載此使用指南LG WD-12EFA
手冊摘要: 使用說明書 LG WD-12EFA
在使用指南中有清楚的使用說明
[. . . ] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] SUB STATUS GROUP ID MODEL ID ADDRESS 11110000 01000011 0011nnnn 00111110 01111111 0ttttttt 0eeeeeee F0 43 3n 3E 7F tt ee
System exclusive message Manufacture’s ID number (LG) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) Universal Data type
2. 8. 3 PARAMETER CHANGE 2. 8. 3. 1 Basic behavior
Reception If [Parameter change ECHO] is ON, these messages are echoed. If [Parameter change RX] is ON and the [Rx CH] matches the Device Number included in the SUB STATUS, these messages are received. A specific parameter is controlled when a Parameter Change is received. When a Parameter Request is received, the current value of the specified parameter will be transmitted as a Parameter Change with the Device Number set to [Rx CH].
Element no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp pp Parameter no.
EOX
0ccccccc cc Channel no. 11110111 F7 End of exclusive
WD-12EFA
2
314
C
MIDI
2. 8. 3. 1. 5 Parameter Address
Consult your dealer for parameter address details. EOX
: : 11110111 F7 End of exclusive
2. 8. 3. 2 Parameter change
STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS 11110000 01000011 0001nnnn 00111110 01111111 00000001 0eeeeeee F0 43 1n 3E 7F 01 ee
(Edit buffer)
System exclusive message Manufacture’s ID number (LG) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) Universal Edit Buffer
2. 8. 3. 7 Parameter request
STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS 11110000 01000011 0011nnnn 00111110 00001101 00000011 0eeeeeee F0 43 3n 3E 0D 03 ee
(Setup memory)
System exclusive message Manufacture’s ID number (LG) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) WD-12EFA Setup data
Element no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp pp Parameter no.
Element no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp pp Parameter no.
DATA EOX
0ccccccc 0ddddddd : 11110111
cc Channel no. 0ddddddd dd data
WD-12EFA
2
MIDI
315
function SCENE RECALL EQ LIB RECALL GATE LIB RECALL COMP LIB RECALL EFF LIB RECALL CHANNEL LIB RECALL INPATCH LIB RECALL OUTPATCH LIB RECALL SCENE STORE EQ LIB STORE GATE LIB STORE COMP LIB STORE EFF LIB STORE CHANNEL LIB STORE INPATCH LIB STORE OUTPATCH LIB STORE
0x00 0x01 0x02 0x03 0x04 0x06 0x07 0x08 0x20 0x21 0x22 0x23 0x24 0x26 0x27 0x28
number 0-99, 8192 1-200, 8192 1-128, 8192 1-128, 8192 1-128, 8192 0-128, 8192 0-32, 8192 0-32, 8192 1-99 41-200 5-128 37-128 xx(*2)-128 1-128 1-32 1-32
channel*1) 256 0-513 0-95 0-513 0-3 0-513 256 256 256, 16383 0-513, 16383 0-31, 16383 0-513, 16383 0-3, 16383 0-513, 16383 256, 16383 256, 16383
tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx
ADDRESS
EOX
00010000 0100ffff 0mmmmmmm 0mmmmmmm 11110111
10 4f mh ml F7
Function call title number High number Low End of exclusive
2. 8. 3. 13 Parameter change (Function call: Scene/Library Clear)
Reception When this is received, the specified memory/library will be cleared. If this is received from Studio Manager or Cascade Link, the operation will be executed, and then the result of execution will be transmitted as a parameter response. Transmission When a memory or library is cleared on the WD-12EFA, this message will be transmitted with the device number set to [Tx CH]. SUB STATUS GROUP ID MODEL ID ADDRESS 11110000 01000011 0001nnnn 00111110 01111111 00010000 0110ffff 0mmmmmmm 0mmmmmmm 11110111 F0 43 1n 3E 7F 10 6f mh ml F7
System exclusive message Manufacture’s ID number (LG) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) Universal Function call clear function number High number Low End of exclusive number 1-99 41-200 5-128 37-128 xx-128 (*1) 1-128 1-32 1-32
*1) 0:CH1 – 31:CH32, 32:ST-IN1L - 39:ST-IN4R, 128:BUS1 – 135:BUS8, 256:AUX1 – 263:AUX8, 512:STEREO Use 256 if the recall destination or store source is a single data item. Effect is 0:Effect 1–3:Effect 4 If the store destination is 16383 (0x3FFF), this indicates that the library data has been changed by a external cause (such as bulk reception) (only transmitted by the WD-12EFA) *2) Varies with the firmware version.
2. 8. 3. 11 Parameter change
(Function call: title)
EOX
Reception When this is received, the title of the specified memory/library will be changed. If this is received from Studio Manager or Cascade Link, the operation will be executed, and then the result of execution will be transmitted as a parameter response. Transmission In response to a request, this is transmitted with the device number set to the [Tx CH]. When the title is changed on the WD-12EFA, this message will be transmitted with the device number set to [Tx CH]. SUB STATUS GROUP ID MODEL ID ADDRESS 11110000 01000011 0001nnnn 00111110 01111111 00010000 0100ffff 0mmmmmmm 0mmmmmmm 0ddddddd : 0ddddddd 11110111 F0 43 1n 3E 7F 10 4f mh ml dd : dd F7
System exclusive message Manufacture’s ID number (LG) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) Universal Function call title number High number Low title 1 : title x(depend on the library) End of exclusive number 0-99, 256(0:response only) 1-200(1-40:response only) 1-128(1-4:response only) 1-128(1-36:response only) 1-128(1-xx(*1):response only) 0-128(0:response only) 0-32(0:response only) 0-32(0:response only) size 16 16 16 16 16 16 16 16
function SCENE LIB CLEAR EQ LIB CLEAR GATE LIB CLEAR COMP LIB CLEAR EFF LIB CLEAR CHANNEL LIB CLEAR INPATCH LIB CLEAR OUTPATCH LIB CLEAR
0x60 0x61 0x62 0x63 0x64 0x66 0x67 0x68
*1) Varies with the firmware version.
2. 8. 3. 14 Parameter change (Function call: attribute)
Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the attribute of the specified memory/library will be changed. [. . . ] 190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
U
UNLATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 OMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 USB USER DEFINED KEYS . . . . . . . . . . . . . . . . . . . . . . . 21 Initial assignments . . . . . . . . . . . . . . . . . . . . . . 249 Utility|Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 . . . . . . . . . . . . . . . . . . . . . . . 73 Utility|CH Status Utility|Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 . . . . . . . . . . . . . . . . . . . . . . 234 Utility|Oscillator Utility | User Def . . . . . . . . . . . . . . . . . . . . . . 235 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 UTILITY
V
VERTICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 View|Fader . . . . . . . . . . . . . . . . [. . . ]
放棄下載這份使用手冊 LG WD-12EFA
Lastmanuals提供軟硬體的使用指南,手冊,快速上手指南,技術資訊的分享,儲存,與搜尋
在任何的情況下, Lastmanuals都沒有任何的責任: 如果您所搜尋的文件結果是不存在的,不完整的,不是您的母語的, 或是型號或語言與描述不符. Lastmanuals不提供翻譯的服務
如果您接受這份合約內容, 請在閱讀完此約後,按下“下載這份使用手冊”, 下載LG WD-12EFA手冊的過程馬上開始.